GE French Door Refrigerator Service Mode, Test Codes and Fault Codes (PFE28, PYE22 and Related)
We typed this up from the two technical data sheets (pub. 31-51919 for the case and 31-51916 for the door, dated 05-15) that came with a GE Profile refrigerator, model PYE22PSHISS. The sheet covers a whole family. Variable speed models: CFE28, CWE23, CYE22, GYE22, PFE28, PFH28, PWE23, PYE22 and ZWE23. Single speed models: DFE28, DFE29, GFE26, GFE27, GFE28, GFE29, GNE26 and GNE29. Some tests only apply to models that have the feature, such as hot water, a deli pan or a feature board. Check the sheet that came with yours.
This is service technician information. The sheet warns of electrical shock hazard and says service should be done by a qualified technician only, with power disconnected before servicing. If you're not trained for that, call a technician.
Entering service diagnostics
- Press the Water, Crushed and Cubed buttons at the same time for 3 seconds.
- The display shows 00 in the freezer temperature display and 00 in the fresh food display. All the components turn off, the 3-way valve goes home, the dampers go to the closed position, and the temperature display shows 00 in each display.
- On LCD displays, use the up and down buttons on the left to change the number.
- Change the ones place to select the test you want. Press any key other than the temperature adjust keys to run it.
- You have to select a test within 5 minutes of entering diagnostics or it times out and the refrigerator goes back to normal.
- Once a test is selected, the display shows the result of the mode.
To exit, run test 0016. The control also resets to normal operation if power is cycled. A non-dispenser model needs a service kit.
The test numbers below are four digits. The first two digits are the freezer display and the last two are the fresh food display. For example, test 14 is entered as 0014, and the exit test is 0016.
Test modes
| Test | Mode | Comments |
|---|---|---|
| 0000 | Show fault codes | |
| 0001 | Clear fault codes | Clear all fault codes after repairs are completed. |
| 0002 | Dispenser self-test mode | Turns on all LEDs and 7-segment digits on the dispenser board for testing. |
| 0006 | COM version | Returns the COM version. Only on LCD models. |
| 0007 | Degrees C mode | Changes the system to degrees C. |
| 0008 | Degrees F mode | Changes the system to degrees F. |
| 0011 | Join Zigbee network | |
| 0012 | Leave Zigbee network | |
| 0013 | Get Zigbee network status | |
| 0014 | Force FF and FZ defrost | Starts a fresh food and freezer defrost. |
| 0015 | Exit all defrost | Forces the heated defrost to the idle state. |
| 0016 | EXIT SERVICE MODE | Resets all boards in the system. |
| 0017 | Door board version test | |
| 0018 | Dispenser version test | |
| 0019 | Deli pan version test | |
| 0020 | Internal temp version test | |
| 0021 | Zigbee module version test | |
| 0022 | AutoFill version test | |
| 0023 | Mainboard version test | Confirms UI communication with this board. |
| 0024 | FF1 thermistor test | Tests 24 to 39 display the unfiltered thermistor temperature. A display of 300 or -41 means open, shorted or not present. Example: 10 27 = 10.27 degrees. |
| 0025 | FF2 thermistor test | |
| 0026 | FF evaporator thermistor test | |
| 0027 | FZ cabinet thermistor test | |
| 0028 | FZ evaporator thermistor test | |
| 0029 | Ambient temp test | |
| 0030 | Deli pan thermistor test | |
| 0031 | FZ ice mold body thermistor test | |
| 0032 | Convertible drawer thermistor test | |
| 0036 | FF door ice mold body thermistor test | |
| 0037 | FF door ice cabinet thermistor test | |
| 0038 | Hot water 1 thermistor test | |
| 0039 | Hot water 2 thermistor test | |
| 0040 | Humidity sensor test | Displays current humidity. |
| 0041 | Case (SxS) flow meter test | Returns the flow from the last dispense for SxS. |
| 0042 | Door (BF) flow meter test | Returns the flow from the last dispense for BF. |
| 0043 | Cycle duct door | Opens the duct door for 10 seconds, then closes it. |
| 0044 | Cycle FF damper | Opens the damper for 30 seconds, then closes it (44 to 46). |
| 0045 | Cycle convertible drawer damper | |
| 0046 | Cycle QC/deli damper | |
| 0047 | FF fan test | Tests 47 to 52 turn the fan on at 75% duty cycle and return the RPM. |
| 0048 | FZ fan test | |
| 0049 | Condenser fan test | |
| 0050 | Ice box fan test | |
| 0051 | Deli/QD fan test | |
| 0052 | Convertible drawer fan test | |
| 0053 | FF defrost heater test | Tests 53 to 69 turn on the load. |
| 0054 | Deli pan/QC heater test | 30 seconds max. |
| 0055 | Isolation valve test | |
| 0056 | Ice port heater test | |
| 0057 | Ice duct liner heater / SxS water valve test | |
| 0058 | FZ icemaker water valve test | |
| 0059 | FZ icemaker rake motor test | |
| 0060 | FZ defrost heater test | |
| 0061 | Compressor relay test | |
| 0063 | IMX power relay test | Normally closed relay. |
| 0064 | FZ icemaker fill tube heater test | |
| 0065 | FF door icemaker water valve test | |
| 0066 | FF door icemaker rake motor test | |
| 0067 | FF door hot water valve test | |
| 0068 | FF door water valve test | |
| 0069 | Hot water heater test | 5 seconds max. |
| 0070 | Read left FF door status | Tests 70 to 73 return the input status (0 = closed, 1 = open). |
| 0071 | Read right FF door status | |
| 0072 | Read FZ door status | |
| 0073 | Read convertible drawer / IM input status | |
| 0074 | Read FZ icemaker rake status | Returns the input status (0 = not home, 1 = home). |
| 0075 | Read FZ icemaker arm status | Returns the input status (0 = not full, 1 = full). |
| 0076 | Read FF door icemaker rake status | Returns the input status (0 = not home, 1 = home). |
| 0077 | Read FF door icemaker arm status | Returns the input status (0 = not full, 1 = full). |
| 0078 | Read FF door cold water cut switch | Tests 78 to 81 return the input status (0 = not pressed / not full). |
| 0079 | Read FF door hot water cup switch | |
| 0080 | Read FF door hot water level switch 1 | |
| 0081 | Read FF door hot water level switch 2 | |
| 0082 | Read FF door overcurrent flag 1 | Returns the input status (0 = not tripped). |
| 0083 | Read FF door overcurrent flag 2 | |
| 0084 | FF door icemaker fill tube heater test | Tests 84 to 89 turn on the load. |
| 0085 | FF door recess heater test | |
| 0086 | Vertical mullion heater test | |
| 0087 | Unused output | |
| 0088 | Unused output | |
| 0089 | Ice box gasket heater test | |
| 0091 | FF lights test | Turns the lights on at 100% duty cycle. |
| 0092 | FZ lights test | |
| 0093 | FZ defrost heater test with feedback | Turns on the FZ defrost heater and displays the FZ evaporator thermistor temperature. |
| 0094 | FF defrost heater test with feedback | Turns on the FF defrost heater and displays the FF evaporator thermistor temperature. |
| 0095 | FF cooling test | Compressor (variable speed high, single speed on), 3-way valve FF/FZ, condenser fan high, FF evaporator fan low. Displays the FF evaporator thermistor temperature. |
| 0096 | FZ cooling test | Compressor (variable speed high, single speed on), 3-way valve FZ only, condenser fan high, FZ evaporator fan low. Displays the FZ evaporator thermistor temperature. |
| 0097 | FF door icemaker heater test | Turns on the FF door I/M heater and displays the FF door I/M mold thermistor temperature. |
| 0098 | FZ icemaker heater test | Turns on the FZ I/M heater and displays the FZ I/M mold thermistor temperature. |
| 0099 | FF door icemaker full cycle test | Full icemaker cycle, similar to a 3-arm press. |
| 0100 | FZ icemaker full cycle test | Entered as 0100. |
| 0101 | RFID board version | Entered as 0101. |
| 0102 | Feature board version | Entered as 0102. |
| 0103 | Air pump and pod valve test | Runs the air pump at 100% duty cycle with the pod valve open. Entered as 0103. |
| 0104 | Air pump and vent valve test | Runs the air pump at 100% duty cycle with the vent valve open. Entered as 0104. |
| 0105 | Raise dispenser nozzle | Runs the motor at 100% duty cycle, raises the nozzle, returns pass/fail. Entered as 0105. |
| 0106 | Lower dispenser nozzle | Runs the motor at 100% duty cycle, lowers the nozzle, returns pass/fail. Entered as 0106. |
| 0107 | Brew module switch test | Returns the brew module switch status. Entered as 0107. |
| 0108 | Turbo heat relay test | Turns on the turbo heat relay only. Entered as 0108. |
| 0109 | Hot water bypass valve test | Turns on the hot water bypass valve relay only. Entered as 0109. |
Failure codes
Run test 0000 to show the fault codes and 0001 to clear them. The sheet groups them by range.
| Code | Group | Definition |
|---|---|---|
| 0001 | Thermistors | FF thermistor reading out of range |
| 0002 | Thermistors | N/A |
| 0003 | Thermistors | FZ thermistor reading out of range |
| 0004 | Thermistors | FZ evaporator thermistor reading out of range |
| 0005 | Thermistors | Electronic deli pan thermistor reading out of range |
| 0006 | Thermistors | FF evaporator thermistor reading out of range |
| 0008 | Thermistors | Ambient temperature thermistor reading out of range |
| 0009 | Thermistors | Ambient humidity sensor reading out of range |
| 0010 | Thermistors | FZ icemaker thermistor reading out of range (if applicable) |
| 0100 | Fans | FZ fan feedback missing when the fan is running |
| 0101 | Fans | FZ fan feedback present when the fan is off |
| 0102 | Fans | FZ fan cannot reach target speed |
| 0103 | Fans | Condenser fan feedback missing when the fan is running |
| 0104 | Fans | Condenser fan feedback present when the fan is off |
| 0105 | Fans | Condenser fan cannot reach target speed |
| 0106 | Fans | FF fan feedback missing when the fan is running |
| 0107 | Fans | FF fan feedback present when the fan is off |
| 0108 | Fans | FF fan cannot reach target speed |
| 0109 | Fans | Ice box fan feedback missing when the fan is running |
| 0110 | Fans | Ice box fan feedback present when the fan is off |
| 0111 | Fans | Ice box fan cannot reach target speed |
| 0112 | Fans | Deli pan fan feedback missing when the fan is running |
| 0113 | Fans | Deli pan fan feedback present when the fan is off |
| 0114 | Fans | Deli pan fan cannot reach target speed |
| 0115 | Fans | Odor remover fan feedback missing when the fan is running |
| 0116 | Fans | Odor remover fan feedback present when the fan is off |
| 0117 | Fans | Odor remover fan cannot reach target speed |
| 0200 | Defrost system | FZ defrost heater timed out (check FZ evaporator thermistor fault code 0004) |
| 0201 | Defrost system | FF defrost heater timed out (check FF evaporator thermistor fault code 0006) |
| 0202 | Defrost system | 5 consecutive FZ extended defrosts |
| 0203 | Defrost system | 5 consecutive FF extended defrosts |
| 0301 | Sealed system | Temperature satisfied for more than 3 hours (no compressor operation) |
| 0303 | Sealed system | FF temperature exceeds 50°F |
| 0304 | Sealed system | FZ temperature exceeds 25°F |
| 0403 | Main board | Mainboard software fault |
| 0404 | Main board | Mainboard hardware fault. The sheet also lists 0404 for "Main board relay driver is shorted". |
| 0500 | Door board | Can't reach target hot water temperature |
| 0501 | Door board | Flow meter: no signal received during dispense |
| 0502 | Door board | Flow meter signal received with no water dispensing |
| 0503 | Door board | Paddle switch pressed for more than 7 minutes |
| 0504 | Door board | Hot water tank not full while heating |
| 0507 | Door board | Check paddle switch and wiring |
| 0508 | Door board | Check paddle switch and wiring |
| 0509 | Door board | Check hot water T&P switch and wiring |
| 0510 | Door board | Check hot water T&P switch and wiring |
| 0511 | Door board | FF IM thermistor reading out of range |
| 0512 | Door board | Ice box thermistor reading out of range |
| 0513 | Door board | Hot water thermistor reading out of range |
| 0514 | Door board | Hot water thermistor reading out of range |
| 0515 | Door board | Door board hardware fault |
| 0516 | Door board | Hot water tank fault |
| 0517 | Door board | Door board hardware fault |
| 0518 | Door board | Low flow rate, hot water disabled |
| 0520 | Door board | HW max fill time out, hot water disabled |
| 0521 | Door board | HW max dispense time out, hot water disabled |
| 0522 | Door board | HW max purge time out, hot water disabled |
| 0523 | Door board | Feature board communication error |
| 0524 | Door board | Dispense nozzle movement error |
| 0525 | Door board | Brew module not detected during brew |
| 0570 | Door board | Dispenser nozzle motor over current error |
| 0571 | Door board | Air valves over current error |
| 0572 | Door board | Air pump over current error |
| 0573 | Door board | Feature board hardware fault |
| 0601 | Ice maker | FF IM harvest extended more than 10 minutes |
| 0602 | Ice maker | FF IM harvest extended 3 out of 10 harvests |
| 0603 | Ice maker | FF IM harvest not completed after 30 minutes |
| 0604 | Ice maker | FF IM no water supply detected |
| 0605 | Ice maker | FF IM continues to sense bucket full after ice dispense |
| 0606 | Ice maker | FF IM mold heater not heating |
| 0651 | Ice maker | FZ IM harvest extended more than 10 minutes |
| 0652 | Ice maker | FZ IM harvest extended 3 out of 10 harvests |
| 0653 | Ice maker | FZ IM harvest not completed after 30 minutes |
| 0654 | Ice maker | FZ IM no water supply detected |
| 0655 | Ice maker | FZ IM mold heater not heating |
| 0700 | External interaction | Stuck keys on dispenser boards |
| 0701 | External interaction | Stuck keys on internal temp board |
| 0702 | External interaction | Stuck keys on deli pan |
| 0703 | External interaction | Key press on temp board while door closed |
| 0704 | External interaction | Key pressed on deli pan board while door closed |
| 0705 | External interaction | Dispenser board auto fill error |
| 0706 | External interaction | Dispenser board auto fill error |
| 0707 | External interaction | Dispenser board error |
| 0708 | External interaction | Dispenser board error |
| 0709 | External interaction | Check paddle switch and wiring |
| 0710 | External interaction | Check paddle switch and wiring |
| 0711 | External interaction | Check hot water T&P switch and wiring |
| 0712 | External interaction | Check hot water T&P switch and wiring |
| 0713 | External interaction | FF door open for 15 minutes continuously |
| 0714 | External interaction | FF door open for 60 minutes total in the last 24 hours |
| 0715 | External interaction | 50 FF left door openings in the last 24 hours |
| 0716 | External interaction | 50 FF right door openings in the last 24 hours |
| 0717 | External interaction | FZ door open for 15 minutes continuously |
| 0718 | External interaction | FZ door open for 60 minutes total in the last 24 hours |
| 0719 | External interaction | 50 FZ door openings in the last 24 hours |
| 0721 | External interaction | Upper auto fill sensor error |
| 0722 | External interaction | Display board error |
| 0800 | RFID | RFID board hardware failure; check filter and filter orientation |
| 0801 | RFID | RFID board failed to respond to the main board |
| 0802 | RFID | RFID board not detecting filter tag; check filter and filter orientation |
| 0803 | RFID | RFID filter authentication failed; check filter and filter orientation |
Specifications
- Electrical rating: 115 VAC, 60 Hz. 9.5 amps on PFE28, DFE29, GFE29, GYE22, PYE22, CWE23, PWE23, ZWE23, GNE29, GNE26, GFE26, DFE28, GFE28, GFE27 and PFH28. 12 amps on CFE28 and CYE22.
- Thermistor resistance at 32°F: 16.3K Ω.
- Over temperature thermostat: 140°F.
- Adaptive defrost control: fresh food 32 hours, freezer 96 hours.
- No load run time at a control position of 37/0: 30 to 55% at 65°F ambient, 55 to 95% at 90°F ambient.
- Static pressures, psig at 55°F, 70°F and 90°F. Single speed (29, 28, 26): 34.8, 48.3, 60.3. Variable speed (22, 23, 29): 25.0, 35.9, 45.3.
Refrigerant charge (R134a), ounces
| Models | Charge |
|---|---|
| PFE28 | 5.375 |
| DFE29, GFE29 | 5.5 |
| GYE22, PYE22, CWE23, PWE23, ZWE23 | 5.25 |
| GNE29, GNE26 | 5.25 |
| GFE26, DFE28, GFE28, GFE27, PFH28 | 5.50 |
| CFE28 | 5.375 |
| CYE22 | 5.25 |
Thermistor resistance
Main thermistors (fresh food, freezer and evaporator):
| °F | °C | kΩ |
|---|---|---|
| -13 | -25 | 65 |
| -4 | -20 | 48.4 |
| 5 | -15 | 36.4 |
| 14 | -10 | 27.6 |
| 23 | -5 | 21 |
| 32 | 0 | 16.3 |
| 41 | 5 | 12.7 |
| 50 | 10 | 10 |
| 59 | 15 | 7.8 |
| 68 | 20 | 6.2 |
| 77 | 25 | 5 |
| 86 | 30 | 4 |
| 95 | 35 | 3.2 |
| 104 | 40 | 2.6 |
Ice maker thermistor:
| °F | °C | kΩ |
|---|---|---|
| -40 | -40 | 207 |
| 35.6 | 2 | 25.37 |
| 39.2 | 4 | 23.27 |
| 50 | 10 | 18.07 |
| 59 | 15 | 14.75 |
| 68 | 20 | 12.11 |
| 77 | 25 | 10 |
| 176 | 80 | 1.67 |
Hot water thermistor:
| °F | °C | kΩ |
|---|---|---|
| 32 | 0 | 32.7 |
| 41 | 5 | 25.4 |
| 77 | 25 | 10 |
| 95 | 35 | 6.5 |
| 122 | 50 | 3.6 |
| 149 | 70 | 2.1 |
| 167 | 75 | 1.5 |
| 185 | 85 | 1.07 |
Fans
All fans have four wires. Red is +12 VDC, black is ground, yellow is the PWM speed signal and blue is the RPM feedback.
- Red to black: 12 VDC constantly.
- Yellow to black: 2 to 3 VDC with the fan on.
- Blue to black: 2 to 4 VDC with the fan on.
Component resistance, cabinet
| Component | Resistance |
|---|---|
| Freshfood defrost heater | 84 Ω |
| Freezer defrost heater | 32 Ω |
| Evaporator duct heater (where applicable) | 6.6 Ω |
| Mullion/enclosure heater (main board) | 142 Ω |
| Ice port heater (where applicable) | 1.12K Ω |
| Freezer icemaker fill tube heater (where applicable) | 1.0K Ω; thermal cutoff opens above 162°F |
| Defrost over-temperature thermostat | Opens above 140°F |
| Isolation water valve | 0.41K Ω |
| Freezer icemaker water valve (where applicable) | 0.4K Ω |
| In-door water valve (where applicable) | 0.41K Ω |
| 3-way valve | White to black, yellow, red or orange: 41 Ω. Black-yellow, yellow-red, red-orange, yellow-orange, black-red, black-orange: 82 Ω each. |
| Single speed compressor DJK51 | Run 6.1 Ω, start 6.7 Ω |
| Single speed compressor DKK51 | Run 5.2 Ω, start 5.9 Ω |
| Variable speed compressor EEI68 | 12.4 Ω |
| Variable speed compressor VEGY6H | 6.4 Ω |
| Variable speed compressor VEGD7H | 7.69 Ω |
Component resistance, door
From the dispenser model door diagram. Which parts you have depends on the model.
| Component | Resistance |
|---|---|
| Speaker | 8.8 Ω |
| Duct door | 185 Ω |
| Recess heater | 146 Ω |
| Fill tube heater | 321 Ω |
| Mullion heater | 25 Ω (12 VDC) |
| Ice box heater | 38 Ω |
| Auger motor (120 VDC) | 125 Ω |
| Ice maker and dispenser water valves | 0.39K Ω each |
| Ice maker rake motor | 2.9K Ω |
| Ice maker mold body heater | 110 Ω |
On the Café models with hot water (CFE28, CYE22) the sheet lists the hot water heater at 19 Ω (café) or 12 Ω (single serve), with a one-shot thermal cutoff that opens above 305°F (152°C). The pod valve and vent valve read 118 Ω each, the air pump 9 Ω and the nozzle motor 185 Ω.